The Clamp Meter is suitable for service technicians, stationary use in repair departments in specialist shops and in laboratories. The Clamp Meter is designed for current measurements up to 400 A AC. In addition to the current clamp function, the measuring clamp offers many functions that only a multimeter otherwise has. The Clamp Meter can also be used as an oscilloscope for simple maintenance applications.
In the oscilloscope mode of the Clamp Meter, in addition to the direct and alternating voltage, the current can also be visualized as a graph. This has the advantage that the waveform of the current can also be displayed on the multimeter. Due to the bandwidth of 200 kHz in oscilloscope mode, the Clamp Meter, this measuring instrument can also be used to measure the current on frequency converters. All functions and areas of the Clamp Meter are protected against overload. The Clamp Meter is suitable for conductor diameters up to 35 x 46 mm.
Measurement parameters | ||
DC voltage | ||
Measuring range | Max. resolution | accuracy |
400 mV | 0.1 mV | ± (1.5% of MW + 10 digits) |
4 V | 0.1 mV | (600 V DC) |
40 V | 0.1 mV | |
400 V. | 0.1 mV | |
600 V | 0.1 mV | |
Measurement parameters | ||
AC voltage | ||
Measuring range | Max. resolution | accuracy |
4 V | 1 mV | ± (2% of meas. + 10 digits) |
40 V | 1 mV | 50 Hz … 2 kHz) |
400 V. | 1 mV | |
600 V | 1 mV | |
Measurement parameters | ||
Alternating current | ||
Measuring range | Max. resolution | accuracy |
40 A | 10 mA | ± (2.5% of MW + 10 digits) |
400 A. | 0.1 A | (400 A / 50 Hz) |
Measurement parameters | ||
frequency | ||
Measuring range | Max. resolution | accuracy |
10 Hz … 30 kHz | 0.1 Hz | ± (1% of MW + 5 digits) |
(4 … 600 V) | ||
Measurement parameters | ||
resistance | ||
Measuring range | Max. resolution | accuracy |
400 Ω | 0.1 Ω | ± (1% of meas. + 5 digits) |
4 kΩ | 0.1 Ω | (400 Ω … 4 MΩ) |
40 kΩ | 0.1 Ω | |
400 kΩ | 0.1 Ω | ± (3% of mw + 5 digits) |
4 MΩ | 0.1 Ω | (40 MΩ) |
40 MΩ | 0.1 Ω | |
Measurement parameters | ||
capacity | ||
Measuring range | Max. resolution | accuracy |
4 nF | 1 pF | ± (4% of meas. + 10 digits) |
40 nF | 1 pF | (4 nF … 400 µF) |
400 nF | 1 pF | |
4 µF | 1 pF | ± (10% of meas. + 15 digits) |
400 µF | 1 pF | (4 mF) |
4 mF | 1 pF | |
Measurement parameters | ||
temperature | ||
Measuring range | Max. resolution | accuracy |
-20 … 250 ° C | 1 ° C | ± (2% + 3 ° C) |
Oscilloscope mode | ||
Usable measurement functions | DC voltage | |
AC voltage | ||
Alternating current | ||
Bandwidth | 2 kHz | |
Sample rate | 2 kSa / s | |
General technical specifications | ||
display | LC display | |
Power supply | 3 x 1.5 V AAA batteries | |
Power consumption | approx. 80 mA | |
Battery life | 180 min | |
Storage | Multimeter mode: 100 data records | |
Oscilloscope mode: 10 waveforms | ||
Operating conditions | 0 … 40 ° C; Max. 75% RH: | |
Storage conditions | -10 … 60 ° C; Max. 90 RH | |
Forceps opening | 35 x 49 mm | |
Dimensions | 212 x 74 x 35 mm | |
Weight | 264 g |