PCE-PA 8300 Power Meter
3-phase / 3 current clamps / LCD graphic display / SD card memory
The PCE-PA 8300 is a Power Meter that features a durable enclosure, SD card memory, a LCD graphic display, as well as apparent, effective, and reactive power measurement. The easy-to-use PCE-PA 8300 Power Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity.
The PCE-PA 8300 is available for purchase in two different configurations:
Set 1: Includes 3 current clamps for measurements up to 1200 A AC
Set 2: Includes 3 flexible Rogowski coils for measurements up to 3000 A AC (for an additional fee)
Please choose either Set 1 or Set 2 before adding the PCE-PA 8300 to your cart.
– Voltage measurement range of 10 V … 600 V AC
– Current measurement range of 20 A … 1200 A AC (Set 1) or 30 A … 3000 A AC (Set 2)
– Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
– Simultaneous display of harmonics and waveform
– Graphic Phasor diagram
– Captures transients including dip, swell, and outage
– SD card memory
– LCD graphic display
– Durable enclosure
– Compatibility with various manufacturers’ power clamps
– Adjustable back-up interval, allowing for long-term data collection
– Auto-setting of measurement range (AC V)
– Power efficiency, delay angle, and frequency measurement
– Apparent, effective, and reactive power measurement
– Harmonic spectrum measurement up to the 50th order
Electrical specifications | ||
Voltage Measurement (AC V) | ||
Measurement Range | Resolution | Accuracy |
10 V … 600 V (phase to neutral) | 0.1 V | ±(0.5 % + 0.5 V) |
10 V … 600 V (phase to phase | 0.1 V | ±(0.5 % + 0.5 V) |
Current Measurement (AC A) Set 1 | ||
Measurement Range | Resolution | Accuracy |
20 A | 0.001 A (< 10 A) 0.01 A (≥ 10 A) | ± (0.5 % + 0.1 A) |
200 A | 0.01 A (< 100 A) 0.1 A (≥ 100 A) | ± (0.5 % + 0.5 A) |
1200 A | 0.1 A (< 1000 A) 1 A (≥ 1000 A) | ± (0.5 A + 5 A) |
Current measurement (AC A) Set 2 | ||
Measurement range | Resolution | Accuracy |
30 A | 0.001 A (< 10 A) 0.01 A (≥ 10 A) | ±(0.5 % + 0.1 A) |
300 A | 0.01 A (< 10 A) 0.1 A (≥ 10 A) | ±(0.5 % + 0.5 A) |
3000 A | 0.1 A (< 1000 A) 1 A (≥ 1000 A) | ±(0.5 A + 5 A) |
Effective power | ||
Measurement range | Resolution | Accuracy |
0 KW … 9.999 KW | 0.001 KW | ±(1 % + 0.008 KW) |
10 KW … 99.99 KW | 0.01 KW | ±(1 % + 0.08 KW) |
100 KW … 999.9 KW | 0.1 KW | ±(1 % + 0.8 KW) |
1 MW … 9.999 MW | 0.001 MW | ±(1 % + 0.008 MW) |
Apparent Power | ||
Measurement range | Resolution | Accuracy |
0 KVA … 9.999 KVA | 0.001 KVA | ±(1 % + 0.008 KVA) |
10 KVA … 99.99 KVA | 0.01 KVA | ±(1 % + 0.08 KVA) |
100 KVA … 999.9 KVA | 0.1 KVA | ±(1 % + 0.8 KVA) |
1 MVA … 9.999 MVA | 0.001 MVA | ±(1 % + 0.008 MVA) |
Reactive Power | ||
Measurement range | Resolution | Accuracy |
0 KVAR … 9.999 KVAR | 0.001 KVAR | ±(1 % + 0.008 KVAR) |
10 KVAR … 99.99 KVAR | 0.01 KVAR | ±(1 % + 0.08 KVAR) |
100 KVAR … 999.9 KVAR | 0.1 KVAR | ±(1 % + 0.8 KVAR) |
1 MVAR … 9.999 MVAR | 0.001 MVAR | ±(1 % + 0.008 MVAR) |
Active Energy | ||
Measurement range | Resolution | Accuracy |
0 KWH … 9.999 KWH | 0.001 KWh | ±(2 % + 0.008 KWh) |
10.00 KWH … 99.99 KWH | 0.01 KWh | ±(2 % + 0.08 KWh) |
100.0 KWH … 999.9 KWH | 0.01 KWh | ±(2 % + 0.8 KWh) |
1 MWH … 9.999 MWH | 0.001 MMh | ±(2 % + 0.008 MWh) |
Apparent Energy | ||
Measurement range | Resolution | Accuracy |
0 KVARH … 9.999 KVARH | 0.001 KVARh | ± (2 % + 0.008 KVARh) |
10.00 KVARH … 99.99 KVARH | 0.01 KVARh | ± (2 % + 0.08 KVARh) |
100.0 KVARH … 999.9 KVARH | 0.01 KVARh | ± (2 % + 0.8 KVARh) |
1 MVARH … 9.999 MVARH | 0.001 MVARh | ± (2 % + 0.008 MVARh) |
Power Factor | ||
Measurement range | Resolution | Accuracy |
0 … 1 | 0.01 | ± 0.04 |
Delay Angle | ||
Measurement range | Resolution | Accuracy |
-180° … +180° | 0.1° | ±1° |
Frequency | ||
Measurement range | Resolution | Accuracy |
45 Hz … 65 Hz | 0.1 Hz | ± 0.1 Hz |
Harmonic of AC Voltage at 50 / 60 Hz | ||
Measurement range | Resolution | Accuracy |
1 … 20th order | 0.001 … 1 A 0.1 % | ± (2 % + 0.5 A) ± (2 % + 10 Digit) |
21 … 30th order | 0.001 … 1 A 0.1 % | ± (2 % + 0.5 A) ± (2 % + 10 Digit) |
21 … 50th order | 0.001 … 1 A 0.1 % | not specified |
General specifications | ||
Display | 3.7 in / 94.0 mm point-matrix LCD (320 * 240 pixel) with LED background lights | |
Safety standards | IEC1010CAT III 600V | |
Input resistance AC V | 10 MOhm | |
Operating frequency of current clamp | 40 Hz … 1 kHz | |
Tested operating frequency of current clamp | 45 Hz … 65 Hz | |
Overload protection | AC V AC A | 720 V RMS 1300 A with current clamp |
Data Storage | SD memory card | |
Refresh interval | 1 second | |
Data logging function | logging with real-time speed on SD memory card | |
Record interval | 2 … 7200 seconds | |
Data output (only for live display on computer) | per USB or RS232, depending on connection cable | |
Operating temperature | 0° C … +50° C / 32° F … 122° F | |
Surrounding humidity | < 80 % RH 8 x 1.5 V AA batteries | |
Voltage Supply | 9 V adapter | |
Current Drain | Measurement Device: 300 mA DC current clamp: 34 mA DC | |
Maximum Wire Diameter | 50 mm / 1.9 in | |
Weight | Measurement Device: 948 g / 33.4 oz (incl. battery) Current clamp: 467 g / 16.4 oz (incl. cable) | |
Dimensions | Device: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in Current clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in Clamp jaw: 86 mm / 3.3 in (exterior) |
รีวิว