PCE-HVAC 6 Digital multimeter
Up to 1000 A AC / DC / Non-contact voltage detection / Voltage measurement up to 600V. Temperature measurement via thermocouple / Robust rubberized housing
Up to 1000 A AC / DC / Non-contact voltage detection / Voltage measurement up to 600V. Temperature measurement via thermocouple / Robust rubberized housing
The digital multimeter PCE-HVAC 6 was specially developed for the tradesman in the field of heating, ventilation and air conditioning technology. This digital multimeter is ideal for many inspection and maintenance jobs in this area. This digital multimeter combines many gauges in one. It is possible with this meter to measure currents up to 1000 A in the DC and AC range via the clamp. Furthermore, voltages up to 600V AC / DC can be determined exactly. For quick and easy testing of electrical conductors, the digital multimeter is equipped with non-contact voltage detection.
The PCE-HVAC 6 digital multimeter can also measure resistors and capacitors. The diode test and continuity test complete the series of electrical measuring functions of the digital multimeter. As a special feature, the PCE-HVAC 6 clamp meter has 2 measuring inputs for Type-K thermocouples. With the help of these thermocouples, for example, the flow and return temperature of heating systems can be measured.
The digital multimeter was developed for the everyday life of a service worker. The sturdy plastic housing withstands shocks easily. A circumferential rubber coating on the housing of the PCE-HVAC 6 helps ensure that the digital multimeter is secure in the hand, even when the technician wears gloves. The display is equipped with an LED backlight, which facilitates reading in dark environments. As a further highlight, the clamp meter on the pliers tip has a measuring point illumination.
– Current measurement up to 1000 A
– Cover of the measuring sockets
– Voltage measurement up to 600V
– Temperature measurement via 2 thermocouples
– Display & measuring point illumination
– Non-contact voltage detection
– Cover of the measuring sockets
– Voltage measurement up to 600V
– Temperature measurement via 2 thermocouples
– Display & measuring point illumination
– Non-contact voltage detection
Current measurement DC A | ||
Measuring range | Resolution | Accuracy (of measured value) |
500 μA | 0.01 μA | ± (1% + 6 digits) |
5000 μA | 0.1 μA | ± (1% + 6 digits) |
50 A | 0.01A | ± (2.5% + 5 digits) |
1000 A | 0.1 A | ± (2.5% + 30 digits) |
Current measurement AC A | ||
Measuring range | Resolution | Accuracy (of measured value) |
500 μA | 0.01 μA | ± (1.5% + 30 digits) |
5000 μA | 0.1 μA | ± (1.5% + 30 digits) |
50 A | 0.01A | ± (2.5% + 30 digits) |
1000 A | 0.1 A | ± (2.8% + 30 digits) |
Note: For AC A measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range | ||
Resistance measurement | ||
Measuring range | Resolution | Accuracy (of measured value) |
500 Ω | 0.01 | ± (1% + 9 digits) |
5 kΩ | 0.0001 | ± (1% + 5 digits) |
50 kΩ | 0.001 | ± (1% + 5 digits) |
500 kΩ | 0.01 | ± (1% + 5 digits) |
5 MΩ | 0.0001 | ± (3% + 10 digits) |
50 MΩ | 0.001 | ± (3.5% + 10 digits) |
Voltage measurement DC V | ||
Measuring range | Resolution | Accuracy (of measured value) |
500 mV | 0.01 mV | ± (0.1 % + 8 Digit) |
5 V | 0.0001 V | ± (0.1 % + 4 Digit) |
50 V | 0.001 V | ± (0.1 % + 4 Digit) |
500 V | 0.01 V | ± (0.1 % + 4 Digit) |
600 V | 0.1 V | ± (0.5 % + 4 Digit) |
Voltage measurement AC V (50 Hz … 100 Hz) | ||
Measuring range | Resolution | Accuracy (of measured value) |
500 mV | 0.01 mV | ± ( 0.8 % + 9 Digit) (at 50 Hz / 60 Hz) |
5 V | 0.0001 V | ± (1 % + 30 Digit) |
50 V | 0.001 V | ± (1 % + 30 Digit) |
500 V | 0.01 V | ± (1 % + 30 Digit) |
600 V | 0.1 V | ± (1 % + 30 Digit) |
Note: For AC V measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range | ||
Capacitance measurement | ||
Measuring range | Resolution | Accuracy (of measured value) |
500 nF | 0.01 | ± (3.5% + 40 digits) |
5000 nF | 0.1 | ± (3.5% + 10 digits) |
50 μF | 0.001 | ± (3.5% + 10 digits) |
500 μF | 0.01 | ± (3.5% + 10 digits) |
5mF | 0.0001 | ± (5% + 10 digits) |
Frequency measurement | ||
Measuring range | Resolution | Accuracy (of measured value) |
50 Hz | 0.001 | ± (0.3% + 2 digits) |
500 Hz | 0.01 | ± (0.3% + 2 digits) |
5 kHz | 0.0001 | ± (0.3% + 2 digits) |
50 khz | 0.001 | ± (0.3% + 2 digits) |
500 kHz | 0.01 | ± (0.3% + 2 digits) |
5 Mhz | 0.0001 | ± (0.3% + 2 digits) |
10 MHz | 0.001 | ± (0.3% + 2 digits) |
Duty cycle | ||
Measuring range | Resolution | Accuracy (of measured value) |
5% … 95% | 0.1 | ± (1% + 2 digits) |
Pulse width: 100 μs … 100 ms� | ||
Frequency: 10 Hz … 10 kHz | ||
Temperature | ||
Measuring range | Resolution | Accuracy (of measured value) |
-100 … 1000°C / -148 … 1832°F | 0.1 | ± (1% + 2.5°C / 3.5°F) |
General technical data | ||
Conductor diameter | Max. 48 mm / 1.9 in | |
Display | Two lines 50,000 digits | |
Continuity test | 50 ohms / < 50 mA | |
Diode test | 0.3 mA / 2.8 V DC | |
Battery indicator | Battery icon when battery low | |
Overrange | OL, if measuring range exceeded | |
Sample rate | 2 Hz | |
Peak detection | > 1 ms | |
Thermocouple | Type K | |
Fuse | 500 mA ceramic quick-acting | |
AC bandwidth (AC A / AC V) | 50 Hz … 400 Hz | |
AC measurement | True RMS | |
Operating conditions | 5 … 40°C / 41 … 104°F, max. 80% RH at 31°C | |
Storage conditions | -20 … 60°C / -4 … 140°F, max. 80% RH | |
Power supply | 9V block battery | |
Automatic shutdown | After about 30 minutes | |
Dimensions (W x H x D) | 230 x 76 x 40 mm / 9 x 3 x 1.6 in | |
Weight | 315 g / < 1 lb | |
Safety | IEC 1010-1 (2001): EN 61010-1 (2001) CAT III 600V CAT II 1000V Degree of pollution 2 |