Digital, electrical, current, voltage or process calibrator, tester or multimeter for simulation and measurement of standardized electrical signals / control signals as well as frequencies and temperature
The PCE-123 is a network-independent multifunction calibrator used to test and calibrate a variety of parameters of controllers and measuring instruments. Offering a high level of accuracy for an affordable price, this easy-to-use calibrator provides electrical (mA, mV, V and frequency in Hz) and temperature (in °C or °F) output signals, making the calibrator useful in a wide range of applications.
The calibrator also has automatic step and ramp functions as well as the possibility to pre-select the output signal steps (0 … 100 %) by using the arrow keys and to directly specify an output value (e. g. 13.8 mA). Operation via the keypad is very easy and intuitive. The PCE-123 multifunctional calibrator is an important tool in any electronics workshop as well as in any measuring and control department in trade, industry and automation.
– 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V
– Type-K, J, E, T temperature thermocouple sensors (°C or °F)
– Frequency range 1 to 62,500Hz
– Basic accuracy 0.025 %
– Easy operation via keypad
– Automatic ramp function
– Selectable between 0 to 20mA/ 0 to 24mA
– Input 0 to 100% (mA, mV, V )
– Alarm beep ‘open’ (mA) or ‘short circuit’ (mV, V)
Technical specifications | |
mA DC current (maximum load at 1kΩ, powered by 24V) | |
Range | 4 to 20mA / 0 to 20mA / 0 to 24mA |
Resolution | 1µA |
Accuracy | ±0.025% ±3µA |
Alert | beeps when there is a short circuit or ouput current >1mA . |
mV current, V DC (power 1mA) | |
Ranges | 0 to 100.00 mV 0 to 10.000 V 0 to 1.0000 V |
Resolution | 10 µV 1 mV 1.0000 V |
Accuracy | ± 0.05% ±30 µV ± 0.05% ±3 mV ± 0.05% ±300 µV |
Alert | beeps when there is a short circuit or ouput current >10mV. |
Temperature sensor thermocouple type-K, J, E, T (1 kΩ min.) | |
Ranges | K: -200 … 0 °C / -328 … 32 °F and 0 … 1370 °C / 32 … 2498 °F J: -100 … 0 °C / -148 … 32 °F and 0 … 760 °C / 32 … 1400 °F E: -10 … 0 °C / 14 … 32 °F and 0 … 700°C / 32 … 1292 °F T: -200 … 0°C / -328 … 32 °F and T: 0 … 400 °C / 32 … 752 °F |
Resolution | 1°C (across entire range) |
Accuracy | K: ±1.1°C and ±0.8°C J: ±0.9°C and ±0.7°C E: ±0.9°C and ±0.7°C T: ±1.0°C and ±0.8°C |
Frequency | |
Range | 1 to 125Hz and 126 to 62.5kHz |
Resolution | 1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings |
Accuracy | ±0.04Hz |
Selection | 604 frequencies |
General characteristics | |
Display | 5 position LCD |
Operating conditions | 0 … 50 °C / 32 … 122 °F <85% r.h. |
Storage conditions | -20 … 60 °C / -4 … 140 °F; <85% r.h. |
Power | 1 9V battery or 6 x 1.5V batteries |
Consumption | 60mA to 180mA (depending on output) |
Battery indicator | 5.5V for 150mA |
Dimensions | 88 x 168 x 26mm / 3.4 x 6.6 x 1 in |
Weight | 330 g / 11.6 oz |