The measured data can be stored on the internal memory of the device. When using the optional RS-232 / RS-485, USB or Ethernet interface, the data can be transferred to a PC. The optional Ethernet interface also allows for remote maintenance. The PCE-KD5 can be operated via its 3.5″ touch screen display, but when using the optional interfaces, it is possible to connect a mouse or keyboard to the device.
Please see drop-down menus above to select desired configuration before ordering.
**Not eligible for 30-day return policy due to custom configuration**
– Up to 24 thermocouple inputs
– Up to 12 inputs for resistance temperature detectors (RTDs)
– Up to 16 relays / solid state relays (SSRs)
– Graphical 3.5″ TFT display with touch screen
– Approximately 30 mathematical functions
– 8 internal PID controllers
– 3 slots for equipping inputs / outputs
– Maximum sampling rate of 10 Hz
– 1.5 GB internal memory
– Optional RS-232 / RS-485, USB or Ethernet interface
– Remote maintenance possible via optional Ethernet interface
Inputs (max.) | 48 analog inputs (0…20 mA or 0…10 V) 48 binary inputs (low: 0…±1 V; high: ±3…±30 V) 24 thermocouple inputs (type J, K, S, T, N, R, B, E) 12 4-wire RTD inputs (Pt100, Pt500, Pt1000) digital input: 1x 24 V DC |
Outputs (max.) | 8 analog outputs (4…20 mA) 16 relays (1A / 250 V) 16 SSRs (100 mA / 15 V) 4 relays (5A / 250 V) |
Transmitter supply | 24 V DC ± 5 %, 200 mA |
Digital interfaces | Standard: 1x RS-485 (Modbus RTU) Optional ETU module: 1x RS-485 1x USB host (rear side) 1x Ethernet Optional ACM module: 2x RS-485 1x RS-485 / RS-232 1x USB host (rear side) 1x Ethernet |
Display | 8.9 cm (3.5″) TFT, graphical, colored (16 bit), 320 x 240 pixels, touch screen |
Power supply | 19 … 50 V DC / 16 … 35 V AC or 85 … 260 V AC/DC |
Power consumption | 15 VA typical, 20 VA max. |
Protection class | Standard: a) IP40 b) IP42 (with transparent, lockable front) c) IP65 (front; only with optional frame) With front USB: a) IP40 b) IP42 (with transparent, lockable front) |
Memory | 1.5 GB (enough for 50 days, 60 channels at 1 Hz samping rate) |
Sampling rate | max. 10 Hz Storing rate: Max. 200 values per second |
Environmental conditions | During operation: 0 … +60 °C During storage: -10 … +70 °C |
Dimensions | 96 x 96 x 100 mm |
Panel cutout | 90.5 x 90.5 mm |