The dB data logger is used to determine volume. The PCE-NDL 10 sound level meter is a handy measuring device that meets the highest requirements. In order to evaluate the measured data as best as possible, it is possible to use the internal measurement data memory on the sound level meter. In addition, the sound level meter has an SD card slot that enables the use of an SD card as an additional storage medium.
The sound data logger is not necessarily a device that has to be used for stationary monitoring of the noise level. After the measurements, the measurement data memories can be read out via the corresponding interfaces. This also enables analyzes. The sampling rate of the noise dosimeter is around one second and the storage interval can be set manually and is between one and 3600 seconds.
However, it must also be taken into account that the internal measured data memory of 16000 values will be filled quickly with a small storage interval and will then automatically overwrite the values measured first and thus delete them irretrievably.
– Low sampling rate
– Automatic or manual storage
– Storage interval selectable
– Backlit LC display
– Dose measurement or SPL measurement
– incl. ISO Calibration Certificate
Type | SPL and dose |
Measuring range | 30 … 130 dB (SPL) / 70 … 130 dB (dose, in 1 dB increments) |
Dose rating levels | 80, 84, 85, 90 dB |
Dose exchange rate | 3, 4, 5 or 6 dB |
Accuracy (at 23 ± 5 ° C, < 94 dB) |
± 3.5 dB (31.5 Hz) ± 2.5 dB (63 Hz) ± 2.0 dB (125 Hz) ± 1.9 dB (250 Hz) ± 1.9 dB (500 Hz) ± 1.4 dB (1000 Hz) ± 2.6 dB (2000 Hz) ± 3.6 dB (4000 Hz) ± 5.6 dB (8000 Hz) |
Resolution | 0.1 dB |
Frequency range | 31.5 … 8000 Hz |
Frequency weighting | A and C |
Time evaluation | 125 ms (fast) / 1 s (slow) |
Data logging | Manual (interval must be set to “0”) or adjustable automatic |
Adjustable auto logging interval | 1 … 3600 s |
Sampling rate | Approx. 1 second |
Storage | Internal memory for up to 16,000 readings, SD card slot for 1 … 4 GB SD card (card included) |
Interface | RS-232 and USB |
Measurement error | ≤ 0.1% of the total stored data |
Measurement outside range | Display of “—-“ |
Functions | Data hold, min / max, date / time, auto shutdown (on / off), audible alarm (on / off) |
Calibration | Internal calibration possible at 94 dB with PCE-SC 42 acoustic calibrator (sold separately – see accessories) |
Power supply | 6 AAA Batteries or optional power supply |
Operating conditions | 0 … +50 ° C (+32 … +122 ° F), < 85% RH |
Display | Backlit LCD, 50 x 30 mm (1.97 x 1.18″) |
Microphone | Electric condensation / Ø 12.7 mm (0.5″) |
Approx. device weight | 250 g (0.56 lb) |
Approx. device dimensions | 132 x 80 x 32 mm (5.20 x 3.15 x 1.26″) |