The HI98196 is a waterproof portable logging multiparameter meter that monitors up to 7 different water quality parameters including 5 measured and 2 calculated. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, dissolved oxygen, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The use of digital communication allows for noise free transfer of data for up to 100 meters in cable length. The complete system is simple to setup and easy to use.
- Multi-Parameter Display
- Multi-sensor Probe
- USB Connection
-
More Information pH Range 0.00 to 14.00 pH pH Resolution 0.01 pH pH Accuracy ±0.02 pH pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer ORP Range ±2000 mV ORP Resolution 0.1 mV ORP Accuracy ±1.0 mV ORP Calibration automatic at one custom point (relative mV) mV Range ±600.0 mV mV Resolution 0.1 mV mV Accuracy ±0.5 mV Dissolved Oxygen Measurement Type polarographic Dissolved Oxygen Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) Dissolved Oxygen Resolution 0.1%; 0.01 ppm (mg/L) Dissolved Oxygen Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3 Dissolved Oxygen Calibration automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L). Dissolved Oxygen Temperature Compensation automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F) Barometric Pressure Compensation automatic from 450 to 850 mmHg Salinity Compensation automatic from 0 to 70 g/L Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa Atmospheric Pressure Accuracy ±3 mm Hg within ±15% from calibration point Atmospheric Pressure Calibration automatic at one custom point Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K Temperature Resolution 0.01 K, 0.01 °C, 0.01 °F Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K Temperature Calibration automatic at one custom point Temperature Compensation automatic from -5 to 55 °C (23 to 131 °F) Logging Memory 45,000 records (continuous logging or log-on-demand of all parameters) Logging Interval one second to three hours Connectivity USB to PC with HI9298194 Hanna software installed Battery Type/Life 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) Environment 0 to 50°C (32 to 122°F); RH 100% (IP67) Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) Weight 400 g (14.2 oz.) Ordering Information HI98196 is supplied with HI7698196 probe, HI7698194-1 pH/ORP sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.